ISSN for PRINT: 0235-7208
Institutional price: |
$109.00 |
Issues per year: |
4 |
2004, Volume1
|
90 pages |
|

|
Issue price - $29.00
|
 |
Uncertainty analysis of one Main Circulation Pump trip event at the Ignalina NPP
Virginijus
Vileiniskis
Lithuanian Energy Institute, Laboratory of Nuclear Installation Safety, Breslaujos 3, LT-3035, Kaunas, Lithuania
Algirdas
Kaliatka
Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, Breslaujos 3, LT-44403 Kaunas, Lithuania
Eugenijus
Uspuras
Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, Breslaujos str. 3, LT-44403 Kaunas, Lithuania
ABSTRACT
One Main Circulation Pump trip event is an anticipated transient with expected frequency of approximately one event per year. There were a few events when one MCP was inadvertently tripped. The throughput of the rest running pumps in the affected Main Circulation Circuit loop increased, however, the total coolant flow through the affected loop decreased. The main question arises whether this coolant flow rate is sufficient for adequate core cooling.
This paper presents an investigation of one MCP trip event at the Ignalina NPP. According to international practice, the transient analysis should consist of deterministic analysis by employing best-estimate codes and uncertainty analysis. For that purpose, the plants RELAP5 model and the GRS (Germany) System for Uncertainty and Sensitivity Analysis package (SUSA) were employed. Uncertainty analysis of flow energy loss in different parts of the Main Circulation Circuit, initial conditions and code-selected models was performed. Such analysis allows to estimate the influence of separate parameters on calculation results and to find the modelling parameters that have the largest impact on the event studied. On the basis of this analysis, recommendations for the further improvement of the model have been developed.
|
|
Article price - $35.00 |
 |
|
 |