Shopping cart ITEMS
 modern scholarly publishers in the finest tradition
Login Register
Home
Books
Journals
References
A-Z Index
Author Index
For Our Authors
User Area
Shopping Cart
Contact
Electronic Data Center

Critical Reviews™ in Biomedical Engineering

 

ISSN for PRINT: 0278-940X

Institutional price:

$1677.00

Issues per year:

6

For Online Access

Best Paper Award Selection - Editorial Board Site

Add subscription to shopping cart

2000, Volume28

Issue 1&2

  356 pages  

   

click 'Save as...' here to save XML metadata

Issue price - $532.00  

Add to shopping cart

  • Enhanced Cardiac Thermal Dilution Analysis for Cardiac Output, Volumes, Stroke Volumes, and Regurgitation Rates — Sensitivity Analysis Using Digital Simulation
  • Francis M. Donovan, Jr.
    Mechanical Engineering Department, University of South Alabama, Mobile, AL 36688

    Bruce C. Taylor
    Biomedical Engineering Department, The University of Akron, Akron, OH 44325


    ABSTRACT

    Cardiac output is measured by placing a double lumen catheter with a thermistor on the tip through the right ventricle into the pulmonary artery, injecting cold saline into the right atrium, and integrating the resulting pulmonary artery temperature profile. If a similar procedure is performed with thermistors located in the right atrium, right ventricle, and pulmonary artery, the resulting temperature curves are determined by the known or easily measured quantities: injectate temperature, injectate volume, heart rate, systolic time interval, body temperature, and time in the cardiac cycle at which injection begins and the unknown quantities: right atrial, right ventricular, pulmonary artery mean and stroke volumes, inflow and outflow valve regurgitation rates, and cardiac output. A digital computer program using a lumped parameter model has been developed to use these quantities to produce thermal dilution curves and optimize the fit of the model curves to the temperature curves from the thermal dilution measurement to determine the unknown quantities. The program is used to investigate the effects of measuring system time constant, heat transfer, and noise on the accuracy of these measurements. The results indicate that the method is practical.

    Download article, 6 pages

    Article price - $35.00  

    Add to shopping cart

    << Previous article   Next article >>

    Designed by offsiteteam Designed by offsiteteam Designed by offsiteteam
    Begell House Inc.
    50 Cross Highway,
    Redding, CT 06896
    TEL (203) 938 1300
    FAX (203) 938 1304
    orders@begellhouse.com