EXPERIMENTAL DATA SET NO. 15: POST DRYOUT HEAT TRANSFER —QUENCH DATA
Peter
Griffith
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 USA
ABSTRACT
Experimental studies on post dryout heat transfer are conducted in an inconel-600 tube (2.44 m long and 10.16 mm ID). A set of unusual quench data are presented in this paper in that liquid N2 is used as the fluid and the absolute temperature ratio, wall to saturation, is as large as about 3. Theoretical modelling is shown to give good prediction by considering the whole boiling curve for liquid N2 after a superheat correction for the vapour is made.
|
|