  • EXPERIMENTAL INVESTIGATION OF FUEL SPRAY VAPOR PHASE CHARACTERIZATION
  • James A. Drallmeier
    University of Missouri - Rolla

    James E. Peters
    Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA


    ABSTRACT

    An experimental study of an infrared laser extinction technique for measuring fuel vapor flux in evaporating liquid fuel sprays was conducted. The infrared laser extinction technique consists of two separate measurements: a visible light angular scattering measurement and an infrared line-of-sight extinction measurement. Using this technique, vapor flux and other spray parameters, such as mean drop size and size distribution, were measured for a pressure-atomized isooctane fuel spray. Line-of-sight infrared extinction measurements were deconvoluted to obtain radial variations of vapor concentration. Peak vapor concentrations were measured at the spray center due to air entrainment effects. Based on the radial mass fraction and measured gas-phase velocity profiles, the fuel vapor mass flux was calculated; most of the vapor flux was contained in the center of the spray at all axial locations. The fuel vapor mass flux was integrated over the spray area at each axial location to obtain fuel vapor mass flow rates. A detailed error analysis was performed to determine the error sensitivities of the vapor concentration to the measured parameters as a function of spray radius. The vapor concentration was relatively insensitive to the measured drop size distribution because vapor absorption was the most dominant mode of extinction. The vapor concentration was most sensitive to the measurement of the infrared extinction ratio. An upper limit for the overall error in the vapor concentration measurement was estimated as 15% over the spray radius.

    Download article, 63-88 pages

    Article price - $35.00  

    Add to shopping cart