Shopping cart ITEMS
 modern scholarly publishers in the finest tradition
Login Register
Home
Books
Journals
References
A-Z Index
Author Index
For Our Authors
User Area
Shopping Cart
Contact
Electronic Data Center

Atomization and Sprays

Journal of the International Institutes for Liquid Atomization and Spray Systems 

ISSN for PRINT: 1045-5110

Institutional price:

$787.00

Issues per year:

8

For Online Access

Best Paper Award Selection - Editorial Board Site

Add subscription to shopping cart

1995, Volume5

Issue 1

  121 pages  

   

click 'Save as...' here to save XML metadata

Issue price - $75.00  

Add to shopping cart

  • SPRAY SIZING BY TOMOGRAPHIC IMAGING
  • C. Oberle
    Department of Mechanical and Aerospace Engineering, State University of New York at Buffalo, Buffalo, New York 14260

    Nasser Ashgriz
    University of Toronto


    ABSTRACT

    A technique for determining the local drop size distribution in liquid sprays is developed. This technique is based on the far-field measurement of the single-wavelength back-scattered light from the spray. A combination of a tomographic imaging technique and the Mie scattering theory is used. The tomographic reconstruction of the spray is realized by using several optical projections, which are obtained by recording the back-scattered light when the spray is illuminated with a coherent and collimated laser beam. Each of these projections corresponds to a specific angular orientation of the spray and a single back-scattering direction. Such an image represents the local time-averaged intensity across the spray for the light scattered in the selected direction. Three tomographic images of the same cross section, corresponding to three different back-scattering directions, are used to determine the local drop size distributions. A log-normal distribution function defined by two variables is assumed, and the scattered light intensity by this distribution is calculated from the Mie theory for the three back-scattering directions. A discrete search technique is then implemented to find the local log-normal distribution that best matches the results provided by the Mie theory and the tomographic images for all three directions. Simulations realized with an axisymmetric spray underline the accuracy of this new method.

    Download article, 45-73 pages

    Article price - $35.00  

    Add to shopping cart

    << Previous article   Next article >>

    Designed by offsiteteam Designed by offsiteteam Designed by offsiteteam
    Begell House Inc.
    50 Cross Highway,
    Redding, CT 06896
    TEL (203) 938 1300
    FAX (203) 938 1304
    orders@begellhouse.com