Shopping cart ITEMS
 modern scholarly publishers in the finest tradition
Login Register
Home
Books
Journals
References
A-Z Index
Author Index
For Our Authors
User Area
Shopping Cart
Contact
Electronic Data Center

Annals of the Assembly for International Heat Transfer Conference 13

 

ISBN 1-56700-225-0 / CD 1-56700-226-9

Volumes per year:

various

For Online Access


Year 2006

• Energy    

DOI: 10.1615/IHTC13.p24    


  • TWO-PHASE FLOW IN ANODE INTERDIGITAL FLOW BED OF A LIQUID FED DIRECT METHANOL FUEL CELL
  • Hang Guo
    Beijing University of Technology

    J. L. Jia
    College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, China

    J. Kong
    College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, China

    F. Ye
    College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, China

    Dr. Chong-Fang Ma
    College of Environmental & Energy Engineering, Beijing University of Technology Beijing 100082, China


    ABSTRACT

    Liquid fed direct methanol fuel cells have drawn increasing attention in recent years. In this paper, a liquid fed direct methanol fuel cell with transparent window was designed and fabricated for visual investigations of carbon dioxide bubbles behaviour and two-phase flow characteristics in anode interdigital flow bed under different operating conditions. The experimental results showed that the electrochemical reaction and two-phase flow interacted each other. The gas void fraction of carbon dioxide gas and mean size of CO2 bubbles increased with increase in current density, as well as cell temperature. The two-phase flow patterns in the interdigital flow bed are different from the phenomena in parallel channels flow bed and serpentine channel flow bed. There were gas columns in the inlet channels. The two-phase flow in outlet channels was bubbly flow. Slug flow was not observed in outlet channels of interdigital flow bed. The typical flow pattern in outlet manifold is slug flow. But bubbly flow and slug flow coexisted in the outlet manifold at low temperature. The effect of input flow rate of methanol solution was also studied. High flow rate was helpful for removal of carbon dioxide bubbles from flow bed.

    ENR-04 pages


    DOI: 10.1615/IHTC13.p24.40


    Download article

    Article price - $35.00  

    Add to shopping cart

    << Previous article   Next article >>

    Designed by offsiteteam Designed by offsiteteam Designed by offsiteteam
    Begell House Inc.
    50 Cross Highway,
    Redding, CT 06896
    TEL (203) 938 1300
    FAX (203) 938 1304
    orders@begellhouse.com