TEMPERATURE MONITORING DURING PLASMA-ARC WELDING AND CLADDING
DOI: 10.1615/ITPPC-1998.460
pages 305-311
Abstract
This paper presents experimental results obtained by IMP-CNRS during plasma-arc welding and cladding using industrial equipment of SMEs (ATN, France - SOUDOBEAM, Belgium).
The pyrometers are laboratory-made devices in the frame of an European B.E. project. They are either one point, high spatial resolution, fast one or two wavelengths systems, or a 2D pyrometer equipped with a lO×lO photodetectors matrix.
Experimental data are discussed to identify the influence of process parameters variation, as well as defects on temperature distribution and to suggest some solutions for process control.
The pyrometers are laboratory-made devices in the frame of an European B.E. project. They are either one point, high spatial resolution, fast one or two wavelengths systems, or a 2D pyrometer equipped with a lO×lO photodetectors matrix.
Experimental data are discussed to identify the influence of process parameters variation, as well as defects on temperature distribution and to suggest some solutions for process control.