F. Castro
Dept. Ingenieria Energetica y Fluidomecanica, E.T.S.I. Industriales, Universidad de Valladolid, Valladolid, Spain
A. Melgar
Dept. Ingenieria Energetica y Fluidomecanica, E.T.S.I. Industriales, Universidad de Valladolid, Valladolid, Spain
F. V. Tinaut
Dept. Ingenieria Energetica y Fluidomecanica, E.T.S.I. Industriales, Universidad de Valladolid, Valladolid, Spain
M. L. Sanchez
Dept. Ingenieria Energetica y Fluidomecanica, E.T.S.I. Industriales, Universidad de Valladolid, Valladolid, Spain
B. Gimenez
Universidad de Valladolid Spain
A non evaporating diesel spray injected at ambient conditions is studied. Droplet size and axial velocity instantaneous profiles are measured by a one component Phase Doppler Anemometer (PDA). The results are presented in the form of correlations. The analysis has revealed a spray structure which is in good agreement with literature data.