Progress in Plasma Processing of Materials, 2001

ISBN Imprimer: 1-56700-165-3

DIGITAL SYSTEM BASED ON CCD CAMERA FOR PARTICLES VELOCITY AND TEMPERATURE MONITORING IN THERMAL SPRAYING

Résumé

Industrial type fully digital diagnostic system was developed in the frame of BRITE Project BE 97-5040 for particles velocity and temperature monitoring in thermal spraying. The system is based on the new CCD structure image sensor that provides higher sensitivity in the near infrared spectral region and higher saturation signal level than the conventional devises. The diagnostic system and special software for image treatment have been tested under actual industrial conditions of plasma spraying (in the range 20-50 kW) of Al203 and Zr02+8%Y203 powders. Diagnostic system demonstrates high performance in plasma spraying monitoring: 20 μm particle size detection limit; 1500 K minimum detectable brightness temperature; 700 mls maximum particle velocity.
Accueil Portail numérique Begell Bibliothèque numérique Begell Revues spécialisées Livres eBooks Références et comptes rendus Auteurs, éditeurs, examinateurs Index A-Z des produits Prix et politiques d'abonnement A propos de Begell House Contactez-nous Language English 中文 Русский 日本語 Português Deutsch Français Español