FOULING OF A SWEET CRUDE OIL UNDER INERT AND OXYGENATED CONDITIONS

Résumé

Fouling of a sweet crude oil derived from oil sands was studied in a re-circulation heating loop to identify causes of refinery pre-heater fouling. Oil was re-circulated for periods of up to six days through an electrically heated annular probe. The oil was maintained under gaseous atmospheres with air/nitrogen molar ratios from zero to 0.25, at total pressures of 460 kPa. The effects of wall and bulk temperature, flow velocity, dissolved oxygen content, and mineral particle additions on the fouling rate are reported.
Accueil Portail numérique Begell Bibliothèque numérique Begell Revues spécialisées Livres eBooks Références et comptes rendus Auteurs, éditeurs, examinateurs Index A-Z des produits Prix et politiques d'abonnement A propos de Begell House Contactez-nous Language English 中文 Русский 日本語 Português Deutsch Français Español