Progress in Plasma Processing of Materials, 2001

ISBN 印刷: 1-56700-165-3

DIGITAL SYSTEM BASED ON CCD CAMERA FOR PARTICLES VELOCITY AND TEMPERATURE MONITORING IN THERMAL SPRAYING

要約

Industrial type fully digital diagnostic system was developed in the frame of BRITE Project BE 97-5040 for particles velocity and temperature monitoring in thermal spraying. The system is based on the new CCD structure image sensor that provides higher sensitivity in the near infrared spectral region and higher saturation signal level than the conventional devises. The diagnostic system and special software for image treatment have been tested under actual industrial conditions of plasma spraying (in the range 20-50 kW) of Al203 and Zr02+8%Y203 powders. Diagnostic system demonstrates high performance in plasma spraying monitoring: 20 μm particle size detection limit; 1500 K minimum detectable brightness temperature; 700 mls maximum particle velocity.
ホーム Begell Digital Portal Begellデジタルライブラリー ジャーナル 書籍 電子書籍 参考文献と会報 著者、編集者、レビュー者 A-Z商品インデックス 価格及び購読のポリシー Begell Houseの概要 連絡先 Language English 中文 Русский 日本語 Português Deutsch Français Español